module ieee802-dot1cb-stream-identification { |
|
yang-version "1.1"; |
|
namespace urn:ieee:std:802.1Q:yang:ieee802-dot1cb-stream-identification; |
|
prefix dot1cb-sid; |
|
import ieee802-types { |
|
prefix ieee; |
|
} |
|
import ieee802-dot1q-types { |
|
prefix dot1qtypes; |
|
} |
|
import ietf-inet-types { |
|
prefix inet; |
|
} |
|
import ietf-interfaces { |
|
prefix if; |
|
} |
|
import ieee802-dot1cb-stream-identification-types { |
|
prefix dot1cb-sid-types; |
|
} |
|
organization |
|
"Institute of Electrical and Electronics Engineers"; |
|
contact |
|
"WG-URL: http://ieee802.org/1/ |
|
WG-EMail: stds-802-1-l@ieee.org |
|
|
|
Contact: IEEE 802.1 Working Group Chair |
|
Postal: C/O IEEE 802.1 Working Group |
|
IEEE Standards Association |
|
445 Hoes Lane |
|
Piscataway, NJ 08854 |
|
USA |
|
|
|
E-mail: stds-802-1-chairs@ieee.org"; |
|
description |
|
"Management objects that control the stream identification from IEEE |
|
Std 802.1CB-2017. This YANG data model conforms to the Network |
|
Management Datastore Architecture defined in RFC 8342. Copyright (C) |
|
IEEE (2021). This version of this YANG module is part of IEEE Std |
|
802.1CBcv; see the draft itself for full legal notices."; |
|
revision 2021-05-06 { |
|
description |
|
"Published as part of IEEE Std 802.1CBcv-2021. Initial version."; |
|
reference |
|
"IEEE Std 802.1CBcv-2021, Frame Replication and Elimination for |
|
Reliability - FRER YANG Data Model and Management Information Base |
|
Module."; |
|
} |
|
identity null-stream-identification { |
|
base dot1cb-sid-types:strid-idty; |
|
description |
|
"Null Stream Identification"; |
|
} |
|
identity smac-vlan-stream-identification { |
|
base dot1cb-sid-types:strid-idty; |
|
description |
|
"Source MAC and VLAN Stream Identification"; |
|
} |
|
identity dmac-vlan-stream-identification { |
|
base dot1cb-sid-types:strid-idty; |
|
description |
|
"Active Destination MAC and VLAN Stream Identification"; |
|
} |
|
identity ip-stream-identification { |
|
base dot1cb-sid-types:strid-idty; |
|
description |
|
"IP Stream Identification"; |
|
} |
|
typedef vlan-tag-identification-type { |
|
type enumeration { |
|
enum tagged { |
|
value 1; |
|
description |
|
"A frame must have a VLAN tag to be recognized as belonging to |
|
the Stream."; |
|
} |
|
enum priority { |
|
value 2; |
|
description |
|
"A frame must be untagged, or have a VLAN tag with a VLAN ID = |
|
0 to be recognized as belonging to the Stream."; |
|
} |
|
enum all { |
|
value 3; |
|
description |
|
"A frame is recognized as belonging to the Stream whether |
|
tagged or not."; |
|
} |
|
} |
|
description |
|
"Enumeration describing how a Stream can be identified using the |
|
VLAN tag."; |
|
} |
|
typedef vlan-identifier-type { |
|
type uint16 { |
|
range "0 .. 4095"; |
|
} |
|
description |
|
"Specifies the vlan_identifier. A value of 0 indicates that the |
|
vlan_identifier carries a special meaning."; |
|
} |
|
list stream-identity { |
|
key "index"; |
|
description |
|
"The Stream identity table consists of a set of tsnStreamIdEntry |
|
objects, each relating to a single Stream, specifying the points in |
|
the system where Stream identification functions are to be |
|
instantiated. Each entry in the Stream identity table has a |
|
tsnStreamIdHandle object specifying a stream_handle value and one |
|
or more tsnStreamIdEntry objects describing one identification |
|
method for that Stream. If a single Stream has multiple |
|
identification methods, perhaps (but not necessarily) on different |
|
ports, then there can be multiple tsnStreamIdEntry objects with the |
|
same value for the tsnStreamIdHandle. If the HSR or PRP method or |
|
the Sequence encode/decode function is applied to a packet, then |
|
the LanId or PathId fields are also used to identify the Stream to |
|
which the packet belongs."; |
|
reference |
|
"9.1. of IEEE Std 802.1CB-2017"; |
|
leaf index { |
|
type uint32; |
|
description |
|
"If a single Stream has multiple identification methods, perhaps |
|
(but not necessarily) on different ports, then there can be |
|
multiple tsnStreamIdEntry objects with the same value for the |
|
tsnStreamIdHandle"; |
|
} |
|
leaf handle { |
|
type uint32; |
|
mandatory true; |
|
description |
|
"The objects in a given entry of the Stream identity table are |
|
used to control packets whose stream_handle subparameter is equal |
|
to the entry’s tsnStreamIdHandle object. The specific values used |
|
in the tsnStreamIdHandle object are not necessarily used in the |
|
system; they are used only to relate the various management |
|
objects in Clause 9 and Clause 10."; |
|
reference |
|
"9.1.1.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
container in-facing { |
|
description |
|
"Container for in-facing Stream identification functions."; |
|
leaf-list input-port { |
|
type if:interface-ref; |
|
description |
|
"The list of ports on which an in-facing Stream identification |
|
function using this identification method is to be placed for |
|
this Stream in the input (coming from the system forwarding |
|
function) direction. Any number of tsnStreamIdEntry objects can |
|
list the same port for the same tsnStreamIdHandle in its |
|
tsnStreamIdInFacInputPortList."; |
|
reference |
|
"9.1.1.4 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf-list output-port { |
|
type if:interface-ref; |
|
description |
|
"The list of ports on which an in-facing Stream identification |
|
function using this identification method is to be placed for |
|
this Stream in the output (towards the system forwarding |
|
function) direction. At most one tsnStreamIdEntry can list a |
|
given port for a given tsnStreamIdHandle in its |
|
tsnStreamIdInFacOutputPortList."; |
|
reference |
|
"9.1.1.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container out-facing { |
|
description |
|
"Container for out-facing Stream identification functions."; |
|
leaf-list input-port { |
|
type if:interface-ref; |
|
description |
|
"The list of ports on which an out-facing Stream identification |
|
function using this identification method is to be placed for |
|
this Stream in the input (coming from the physical interface) |
|
direction. Any number of tsnStreamIdEntry objects can list the |
|
same port for the same tsnStreamIdHandle in its |
|
tsnStreamIdOutFacInputPortList."; |
|
reference |
|
"9.1.1.5 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf-list output-port { |
|
type if:interface-ref; |
|
description |
|
"The list of ports on which an out-facing Stream identification |
|
function using this identification method is to be placed for |
|
this Stream in the output (towards the physical interface) |
|
direction. At most one tsnStreamIdEntry can list a given port |
|
for a given tsnStreamIdHandle in its |
|
tsnStreamIdOutFacOutputPortList."; |
|
reference |
|
"9.1.1.3 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
choice parameters { |
|
mandatory true; |
|
description |
|
"The number of controlling parameters for a Stream identification |
|
method, their types and values, are specific to the |
|
tsnStreamIdIdentificationType."; |
|
reference |
|
"9.1.1.7 of IEEE Std 802.1CB-2017"; |
|
container null-stream-identification { |
|
description |
|
"When instantiating an instance of the Null Stream |
|
identification function for a particular input Stream, the |
|
managed objects in this container serve as the |
|
tsnStreamIdParameters managed object."; |
|
reference |
|
"9.1.2 of IEEE Std 802.1CB-2017"; |
|
container identification-type { |
|
config false; |
|
description |
|
"The identification type indicating the method used to |
|
identify packets belonging to the Stream. The identification |
|
type contains a type number and an Organizationally Unique |
|
Identifier (OUI) or Company ID (CID) to identify the |
|
organization defining the identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
leaf type-number { |
|
type dot1cb-sid-types:stream-id-function; |
|
default "null-stream"; |
|
description |
|
"The stream identification type used for the Null Stream |
|
identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf oui-cid { |
|
type string { |
|
pattern "[0-9A-F]{2}(-[0-9A-F]{2}){2}"; |
|
} |
|
default "00-80-C2"; |
|
description |
|
"The Organizationally Unique Identifier (OUI) or Company ID |
|
(CID) to identify the organization defining the |
|
identification method. For identification methods defined |
|
in IEEE Std 802.1CB-2017 the OUI/CID is always 00-80-C2."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
leaf destination-mac { |
|
type ieee:mac-address; |
|
description |
|
"Specifies the destination_address that identifies a packet |
|
in an EISS indication primitive, to the Null Stream |
|
identification function. The ieee:mac-address type has a |
|
pattern that allows upper and lower case letters. To avoid |
|
issues with string comparison, it is suggested to only use |
|
Upper Case for the letters in the hexadecimal numbers. There |
|
is still an issue with a difference between the IETF |
|
mac-address definition and the IEEE mac-address definition, |
|
so consider that if implementing code that compares |
|
mac-addresses."; |
|
reference |
|
"9.1.2.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf tagged { |
|
type vlan-tag-identification-type; |
|
description |
|
"An enumerated value indicating whether a packet in an EISS |
|
indication primitive to the Null Stream identification |
|
function is permitted to have a VLAN tag."; |
|
reference |
|
"9.1.2.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf vlan { |
|
type vlan-identifier-type; |
|
description |
|
"Specifies the vlan_identifier parameter that identifies a |
|
packet in an EISS indication primitive to the Null Stream |
|
identification function. A value of 0 indicates that the |
|
vlan_identifier parameter is ignored on EISS indication |
|
primitives."; |
|
reference |
|
"9.1.2.3 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container smac-vlan-stream-identification { |
|
description |
|
"When instantiating an instance of the Source MAC and VLAN |
|
Stream identification function for a particular input Stream, |
|
the managed objects in the following subclauses serve as the |
|
tsnStreamIdParameters managed object."; |
|
reference |
|
"9.1.3 of IEEE Std 802.1CB-2017"; |
|
container identification-type { |
|
config false; |
|
description |
|
"The identification type indicating the method used to |
|
identify packets belonging to the Stream. The identification |
|
type contains a type number and an Organizationally Unique |
|
Identifier (OUI) or Company ID (CID) to identify the |
|
organization defining the identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
leaf type-number { |
|
type dot1cb-sid-types:stream-id-function; |
|
default "smac-vlan"; |
|
description |
|
"The stream identification type used for the Source MAC and |
|
VLAN Stream identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf oui-cid { |
|
type string { |
|
pattern "[0-9A-F]{2}(-[0-9A-F]{2}){2}"; |
|
} |
|
default "00-80-C2"; |
|
description |
|
"The Organizationally Unique Identifier (OUI) or Company ID |
|
(CID) to identify the organization defining the |
|
identification method. For identification methods defined |
|
in IEEE Std 802.1CB-2017 the OUI/CID is always 00-80-C2."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
leaf source-mac { |
|
type ieee:mac-address; |
|
description |
|
"Specifies the source_address that identifies a packet in an |
|
EISS indication primitive, to the Source MAC and VLAN Stream |
|
identification function. The ieee:mac-address type has a |
|
pattern that allows upper and lower case letters. To avoid |
|
issues with string comparison, it is suggested to only use |
|
Upper Case for the letters in the hexadecimal numbers. There |
|
is still an issue with a difference between the IETF |
|
mac-address definition and the IEEE mac-address definition, |
|
so consider that if implementing code that compares |
|
mac-addresses."; |
|
reference |
|
"9.1.3.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf tagged { |
|
type vlan-tag-identification-type; |
|
description |
|
"An enumerated value indicating whether a packet in an EISS |
|
indication primitive to the Source MAC and VLAN Stream |
|
identification function is permitted to have a VLAN tag."; |
|
reference |
|
"9.1.3.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf vlan { |
|
type vlan-identifier-type; |
|
description |
|
"Specifies the vlan_identifier parameter that identifies a |
|
packet in an EISS indication primitive to the Source MAC and |
|
VLAN Stream identification function. A value of 0 indicates |
|
that the vlan_identifier parameter is ignored on EISS |
|
indication primitives."; |
|
reference |
|
"9.1.3.3 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container dmac-vlan-stream-identification { |
|
description |
|
"When instantiating an instance of the Active Destination MAC |
|
and VLAN Stream identification function for a particular output |
|
Stream, the managed objects in the following subclauses, along |
|
with those listed in 9.1.2, serve as the tsnStreamIdParameters |
|
managed object."; |
|
reference |
|
"9.1.4 of IEEE Std 802.1CB-2017"; |
|
container identification-type { |
|
config false; |
|
description |
|
"The identification type indicating the method used to |
|
identify packets belonging to the Stream. The identification |
|
type contains a type number and an Organizationally Unique |
|
Identifier (OUI) or Company ID (CID) to identify the |
|
organization defining the identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
leaf type-number { |
|
type dot1cb-sid-types:stream-id-function; |
|
default "dmac-vlan"; |
|
description |
|
"The stream identification type used for the Active |
|
Destination MAC and VLAN Stream identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf oui-cid { |
|
type string { |
|
pattern "[0-9A-F]{2}(-[0-9A-F]{2}){2}"; |
|
} |
|
default "00-80-C2"; |
|
description |
|
"The Organizationally Unique Identifier (OUI) or Company ID |
|
(CID) to identify the organization defining the |
|
identification method. For identification methods defined |
|
in IEEE Std 802.1CB-2017 the OUI/CID is always 00-80-C2."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container down { |
|
description |
|
"Container for all parameters which are sent to lower layers."; |
|
leaf destination-mac { |
|
type ieee:mac-address; |
|
description |
|
"Specifies the destination_address parameter to use in the |
|
EISS request primitive for output packets sent to lower |
|
layers by the Active Destination MAC and VLAN Stream |
|
identification function, and the destination_address that |
|
identifies an input packet in an EISS indication primitive |
|
to the Active Destination MAC and VLAN Stream |
|
identification function. The ieee:mac-address type has a |
|
pattern that allows upper and lower case letters. To avoid |
|
issues with string comparison, it is suggested to only use |
|
Upper Case for the letters in the hexadecimal numbers. |
|
There is still an issue with a difference between the IETF |
|
mac-address definition and the IEEE mac-address definition, |
|
so consider that if implementing code that compares |
|
mac-addresses."; |
|
reference |
|
"9.1.4.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf tagged { |
|
type vlan-tag-identification-type; |
|
description |
|
"An enumerated value indicating whether a packet in an EISS |
|
indication or request primitive between the Active |
|
Destination MAC and VLAN Stream identification function and |
|
the lower layers is to have a VLAN tag. This variable is |
|
not used in an FRER C-component. See 8.4."; |
|
reference |
|
"9.1.4.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf vlan { |
|
type vlan-identifier-type; |
|
description |
|
"Specifies the vlan_identifier parameter to use in the EISS |
|
request primitive for output packets sent to lower layers |
|
by the Active Destination MAC and VLAN Stream |
|
identification function, and the vlan_identifier that |
|
identifies an input packet in an EISS indication primitive |
|
to the Active Destination MAC and VLAN Stream |
|
identification function. A value of 0 indicates that the |
|
vlan_identifier parameter is ignored on EISS indication |
|
primitives."; |
|
reference |
|
"9.1.4.3 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf priority { |
|
type dot1qtypes:priority-type; |
|
description |
|
"Specifies the priority parameter to use in the EISS |
|
request primitive for output packets sent to lower layers |
|
by the Active Destination MAC and VLAN Stream |
|
identification function for all packets in a particular |
|
Stream."; |
|
reference |
|
"9.1.4.4 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container up { |
|
description |
|
"Container for all parameters which are offered to higher |
|
layers."; |
|
leaf destination-mac { |
|
type ieee:mac-address; |
|
description |
|
"Specifies the destination_address parameter to use in the |
|
EISS indication primitive for input packets offered to |
|
upper layers by the Active Destination MAC and VLAN Stream |
|
identification layer. This address replaces the address |
|
that was used to identify the packet |
|
(tsnCpeDmacVlanDownDestMac). The ieee:mac-address type has |
|
a pattern that allows upper and lower case letters. To |
|
avoid issues with string comparison, it is suggested to |
|
only use Upper Case for the letters in the hexadecimal |
|
numbers. There is still an issue with a difference between |
|
the IETF mac-address definition and the IEEE mac-address |
|
definition, so consider that if implementing code that |
|
compares mac-addresses."; |
|
reference |
|
"9.1.4.5 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf tagged { |
|
type vlan-tag-identification-type; |
|
description |
|
"An enumerated value indicating whether a packet in an EISS |
|
indication or request primitive between the Active |
|
Destination MAC and VLAN Stream identification function and |
|
the upper layers is to have a VLAN tag. This variable is |
|
used only by an end system and not by a relay system."; |
|
reference |
|
"9.1.4.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf vlan { |
|
type vlan-identifier-type; |
|
description |
|
"Specifies the vlan_identifier parameter to use in the EISS |
|
indication primitive for packets offered to upper layers, |
|
or the VLAN ID field for an IEEE 802.1Q tag in an ISS |
|
mac_service_data_unit. This address replaces the VLAN ID |
|
that was used to identify the packet |
|
(tsnCpeDmacVlanDownVlan)."; |
|
reference |
|
"9.1.4.7 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf priority { |
|
type dot1qtypes:priority-type; |
|
description |
|
"Specifies the priority parameter to use in the EISS |
|
indication primitive for packets offered to upper layers."; |
|
reference |
|
"9.1.4.8 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
} |
|
container ip-stream-identification { |
|
description |
|
"When instantiating an instance of the IP Stream identification |
|
function, the parameters in the following subclauses replace |
|
the tsnStreamIdParameters managed object."; |
|
reference |
|
"9.1.5 of IEEE Std 802.1CB-2017"; |
|
container identification-type { |
|
config false; |
|
description |
|
"The identification type indicating the method used to |
|
identify packets belonging to the Stream. The identification |
|
type contains a type number and an Organizationally Unique |
|
Identifier (OUI) or Company ID (CID) to identify the |
|
organization defining the identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
leaf type-number { |
|
type dot1cb-sid-types:stream-id-function; |
|
default "ip"; |
|
description |
|
"The stream identification type used for the IP Stream |
|
identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf oui-cid { |
|
type string { |
|
pattern "[0-9A-F]{2}(-[0-9A-F]{2}){2}"; |
|
} |
|
default "00-80-C2"; |
|
description |
|
"The Organizationally Unique Identifier (OUI) or Company ID |
|
(CID) to identify the organization defining the |
|
identification method. For identification methods defined |
|
in IEEE Std 802.1CB-2017 the OUI/CID is always 00-80-C2."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
leaf destination-mac { |
|
type ieee:mac-address; |
|
description |
|
"Specifies the destination_address parameter that identifies |
|
a packet in an EISS indication primitive. The |
|
ieee:mac-address type has a pattern that allows upper and |
|
lower case letters. To avoid issues with string comparison, |
|
it is suggested to only use Upper Case for the letters in the |
|
hexadecimal numbers. There is still an issue with a |
|
difference between the IETF mac-address definition and the |
|
IEEE mac-address definition, so consider that if implementing |
|
code that compares mac-addresses."; |
|
reference |
|
"9.1.5.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf tagged { |
|
type vlan-tag-identification-type; |
|
description |
|
"An enumerated value indicating whether a packet in an EISS |
|
indication or request primitive to the IP Stream |
|
identification function is to have a VLAN tag."; |
|
reference |
|
"9.1.5.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf vlan { |
|
type vlan-identifier-type; |
|
description |
|
"Specifies the vlan_identifier parameter that identifies a |
|
packet in an EISS indication primitive. A value of 0 |
|
indicates that the frame is not to have a VLAN tag."; |
|
reference |
|
"9.1.5.3 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf ip-source { |
|
type inet:ip-address; |
|
description |
|
"Specifies the IPv4 (RFC 791) or IPv6 (RFC 2460) source |
|
address parameter that must be matched to identify packets |
|
coming up from lower layers. An address of all 0 indicates |
|
that the IP source address is to be ignored on packets |
|
received from lower layers."; |
|
reference |
|
"9.1.5.4 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf ip-destination { |
|
type inet:ip-address; |
|
description |
|
"Specifies the IPv4 (RFC 791) or IPv6 (RFC 2460) destination |
|
address parameter that must be matched to identify packets |
|
coming up from lower layers."; |
|
reference |
|
"9.1.5.5 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf dscp { |
|
type inet:dscp; |
|
description |
|
"Specifies the IPv4 (RFC 791) or IPv6 (RFC 2460) |
|
differentiated services codepoint (DSCP, RFC 2474) that must |
|
be matched to identify packets coming up from the lower |
|
layers. A value of 64 decimal indicates that the DSCP is to |
|
be ignored on packets received from lower layers."; |
|
reference |
|
"9.1.5.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf next-protocol { |
|
type enumeration { |
|
enum none { |
|
description |
|
"No protocol is specified"; |
|
} |
|
enum udp { |
|
description |
|
"UDP is specified as the next protocol."; |
|
reference |
|
"RFC 768"; |
|
} |
|
enum tcp { |
|
description |
|
"TCP is specified as the next protocol."; |
|
reference |
|
"RFC 793"; |
|
} |
|
enum sctp { |
|
description |
|
"SCTP is specified as the next protocol."; |
|
reference |
|
"RFC 4960"; |
|
} |
|
} |
|
description |
|
"Specifies the IP next protocol parameter that must be |
|
matched to identify packets coming up from lower layers. The |
|
value of this parameter must specify either none, UDP (RFC |
|
768), TCP (RFC 793), or SCTP (RFC 4960). If “none,” then the |
|
tsnCpeIpIdSourcePort and tsnCpeIpIdDestinationPort managed |
|
objects are not used."; |
|
reference |
|
"9.1.5.7 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf source-port { |
|
type inet:port-number; |
|
description |
|
"Specifies the TCP or UDP Source Port parameter that must be |
|
matched to identify packets coming up from lower layers. A |
|
value of 0 indicates that the Source Port number of the |
|
packet is to be ignored on packets received from lower |
|
layers."; |
|
reference |
|
"9.1.5.8 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf destination-port { |
|
type inet:port-number; |
|
description |
|
"Specifies the TCP or UDP Destination Port parameter that |
|
must be matched to identify packets coming up from lower |
|
layers. A value of 0 indicates that the Destination Port |
|
number of the packet is to be ignored on packets received |
|
from lower layers."; |
|
reference |
|
"9.1.5.9 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
container organization-specific { |
|
description |
|
"This container allows to select stream identification methods |
|
that are defined by entities outside of IEEE 802.1."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
container identification-type { |
|
description |
|
"The identification type indicating the method used to |
|
identify packets belonging to the Stream. The identification |
|
type contains a type number and an Organizationally Unique |
|
Identifier (OUI) or Company ID (CID) to identify the |
|
organization defining the identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
leaf type-number { |
|
type int32 { |
|
range "256..max"; |
|
} |
|
description |
|
"The type number used for an identification method defined |
|
by an entity owning the OUI or CID for this identification |
|
type."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf oui-cid { |
|
type string { |
|
pattern "[0-9A-F]{2}(-[0-9A-F]{2}){2}"; |
|
} |
|
description |
|
"The Organizationally Unique Identifier (OUI) or Company ID |
|
(CID) to identify the organization defining the |
|
identification method."; |
|
reference |
|
"9.1.1.6 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
} |
|
} |
|
} |
|
augment "/if:interfaces/if:interface/if:statistics" { |
|
description |
|
"The following counters are the counters for stream identification. |
|
All counters are unsigned integers. If used on links faster than |
|
650 000 000 bits per second, they shall be 64 bits in length to |
|
ensure against excessively short wrap times."; |
|
reference |
|
"9.2 of IEEE Std 802.1CB-2017 |
|
9.3 of IEEE Std 802.1CB-2017"; |
|
container stream-id { |
|
description |
|
"This container contains the per-port as well as the |
|
per-port-per-stream counters for stream identification."; |
|
reference |
|
"9.2 of IEEE Std 802.1CB-2017 |
|
9.3 of IEEE Std 802.1CB-2017"; |
|
container per-port-counters { |
|
config false; |
|
description |
|
"Contains the per-port counters for stream identification. The |
|
following counters are instantiated for each port on which the |
|
Stream identification function is configured. The counters are |
|
indexed by port number."; |
|
reference |
|
"9.3 of IEEE Std 802.1CB-2017"; |
|
leaf input-pkts { |
|
type uint64; |
|
config false; |
|
description |
|
"The tsnCpSidInputPackets counter is incremented once for |
|
each packet identified by any Stream identification function |
|
on this port. Its value equals the sum (modulo the size of |
|
the counters) of all of the tsnCpsSidInputPackets counters on |
|
this same port."; |
|
reference |
|
"9.3.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf output-pkts { |
|
type uint64; |
|
config false; |
|
description |
|
"The tsnCpSidOutputPackets counter is incremented once for |
|
each packet passed down the stack by any Stream |
|
identification function on this port. Its value equals the |
|
sum (modulo the size of the counters) of all of the |
|
tsnCpsSidOutputPackets counters on this same port."; |
|
reference |
|
"9.3.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
list per-port-per-stream-counters { |
|
key "direction-out-facing handle"; |
|
config false; |
|
description |
|
"Contains the per-port-per-stream counters for stream |
|
identification. The following counters are instantiated for |
|
each port on which the Stream identification function is |
|
configured. The counters are indexed by port number, facing |
|
(in-facing or out-facing), and stream_handle value |
|
(tsnStreamIdHandle)."; |
|
reference |
|
"9.2 of IEEE Std 802.1CB-2017"; |
|
leaf direction-out-facing { |
|
type dot1cb-sid-types:direction; |
|
description |
|
"An object indicating whether the counters apply to |
|
out-facing (True) or in-facing (False)."; |
|
} |
|
leaf handle { |
|
type leafref { |
|
path '/stream-identity/handle'; |
|
} |
|
description |
|
"The according tsnStreamIdHandle for these counters."; |
|
} |
|
leaf input-pkts { |
|
type uint64; |
|
description |
|
"The tsnCpsSidInputPackets counter is incremented once for |
|
each packet identified by the Stream identification function."; |
|
reference |
|
"9.2.1 of IEEE Std 802.1CB-2017"; |
|
} |
|
leaf output-pkts { |
|
type uint64; |
|
description |
|
"The tsnCpsSidOutputPackets counter is incremented once for |
|
each packet passed down the stack by the Stream |
|
identification function."; |
|
reference |
|
"9.2.2 of IEEE Std 802.1CB-2017"; |
|
} |
|
} |
|
} |
|
} |
|
}
|
|
|